Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 28
Filtrar
1.
Otol Neurotol ; 45(3): e206-e213, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38361306

RESUMO

INTRODUCTION: Electrically evoked compound action potentials (ECAPs) are used for intra-/postoperative monitoring with intracochlear stimulation of cochlear implants. ECAPs are recorded in MED-EL (Innsbruck, Austria) implants using auditory response telemetry (ART), which has been further developed with automatic threshold determination as AutoART. The success of an ECAP measurement also depends on the number of available spiral ganglion cells and the bipolar neurons of the cochlear nerve (CN). It is assumed that a higher population of spiral ganglion cell implies a larger CN cross-sectional area (CSA), which consequently affects ECAP measurements. METHODS: Intraoperative ECAP measurements from 19 implanted ears of children aged 8 to 18 months were retrospectively evaluated. A comparison and correlation of ART/AutoART ECAP thresholds/slopes at electrodes E2 (apical), E6 (medial), E10 (basal), and averaged E1 to E12 with CN CSA on magnetic resonance imaging was performed. RESULTS: A Pearson correlation of the ART/AutoART ECAP thresholds/slopes for E2/E6/E10 and the averaged electrodes E1 to E12 showed a significant correlation. The CN CSA did not correlate significantly with the averaged ART/AutoART ECAP thresholds/slopes across all 12 electrodes. SUMMARY: AutoART provides reliable measurements and is therefore a suitable alternative to ART. No significant influence of CN CSA on ECAP thresholds/slopes was observed. A predictive evaluation of the success of ECAP measurements based on CN CSA for a clinical setting cannot be made according to the present data.


Assuntos
Implante Coclear , Implantes Cocleares , Criança , Lactente , Humanos , Pré-Escolar , Estudos Retrospectivos , Potenciais Evocados Auditivos/fisiologia , Implante Coclear/métodos , Nervo Coclear/fisiologia , Potenciais de Ação/fisiologia , Estimulação Elétrica
2.
Artigo em Inglês | MEDLINE | ID: mdl-38219245

RESUMO

PURPOSE: The purpose of this retrospective study is to compare the results of electrically evoked compound action potential (ECAP) measurements using automatic auditory response telemetry (AutoART) with those obtained by ART in adults. The study also aimed to evaluate the predictive value of intraoperative ART and AutoART ECAPs for speech intelligibility (SI) and hearing success (HS), and to determine if cochlear nerve (CN) cross-sectional area (CSA) obtained preoperatively by magnetic resonance imaging (MRI) scans could predict ART and AutoART ECAPs and SI and HS outcome. METHODS: The study analyzed and correlated ART and AutoART ECAP thresholds at electrodes E2, E6, and E10, as well as averaged ECAP thresholds over electrodes E1-E12, using data from 32 implants. Correlations were also examined for ART and AutoART ECAP slopes. In addition, averaged ART and AutoART ECAP thresholds and slopes over all 12 electrodes for each participant were correlated with CN CSA measured from MRI sequences. SI of the monosyllabic Freiburg Speech Test at 65 dB sound pressure level was examined along with averaged ART and AutoART thresholds and slopes over all 12 electrodes. A parallel analysis was performed for HS, derived from the difference between baseline and 6-month SI. Finally, correlations between CN CSA and SI, as well as CN CSA and HS were examined. RESULTS: The results of the study showed a significant positive correlation between ART and AutoART ECAP thresholds and as well as slopes for E2, E6, E10 and averaged thresholds and slopes of E1-E12. However, no significant correlation was observed between ART and AutoART averaged ECAP thresholds and slopes and either SI and HS or CN CSA. Furthermore, no significant correlation was found between CN CSA and SI and HS. CONCLUSION: While AutoART is a reliable and safe program for measuring ECAPs in adults, the study found no preoperative prognostic information on intraoperative ECAP results using parameters extracted from current MRI sequences or pre-/intraoperative information on subsequent hearing outcome using ECAP and CN CSA.

3.
HNO ; 72(Suppl 1): 17-24, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37608133

RESUMO

BACKGROUND: The hearing success of patients with bimodal fitting, utilizing both a cochlear implant (CI) and a hearing aid (HA), varies considerably: While some patients benefit from bimodal CI and HA, others do not. OBJECTIVES: This retrospective study aimed to investigate speech perception in bimodally fitted patients and compare it with the cochlear coverage (CC). METHODS: The CC was calculated with the OTOPLAN software, measuring the cochlear duct length on temporal bone CT scans of 39 patients retrospectively. The patients were categorized into two groups: CC ≤ 65% (CC500) and CC > 65% (CC600). Monaural speech intelligibility for monosyllables at a sound pressure level (SPL) of 65 dB in a free-field setting was assessed before and after CI at various time points. The two groups, one with preoperative HA and one with postoperative CI, were compared. Additionally, speech intelligibility was correlated with CC in the entire cohort before CI and at the last available follow-up (last observation time, LOT). RESULTS: Overall, there was no significant difference in speech intelligibility between CC500 and CC600 patients, with both groups demonstrating a consistent improvement after implantation. While CC600 patients tended to exhibit earlier improvement in speech intelligibility, CC500 patients showed a slower initial improvement within the first 3 months but demonstrated a steeper learning curve thereafter. At LOT, the two patient groups converged, with no significant differences in expected speech intelligibility. There was no significant relationship between unimodal/unilateral free-field speech intelligibility and CC. Interestingly, patients with a CC of 70-75% achieved the highest speech intelligibility. CONCLUSION: Despite of the lack of a significant correlation between CC and speech perception, patients appeared to reach their maximum in unimodal/unilateral speech perception primarily at a coverage level of 70-75%. Nevertheless, further investigation is warranted, as CC500 was associated with shorter cochlear duct length, and different types of electrodes were used in both groups.


Assuntos
Implante Coclear , Implantes Cocleares , Auxiliares de Audição , Percepção da Fala , Humanos , Estudos Retrospectivos
4.
Eur Arch Otorhinolaryngol ; 281(2): 639-647, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37470816

RESUMO

PURPOSE: The focus on treating patients with Menière's Disease (MD) lies on the reduction of vertigo attacks and the preservation of sensory function. Endolympathic hydrops is considered as an epiphenomenon in MD, which can potentially be altered by endolymphatic sac surgery (ESS). Purpose of the study was to investigate the influences on vertigo control through manipulation of the perilymphatic system with or without ESS. METHODS: Retrospective data analysis of 86 consecutive patients with MD according to current diagnostic criteria after endolymphatic sac surgery alone (ESSalone; n = 45), cochlear implantation (CI) alone (CIalone; n = 12), and ESS with CI (ESS + CI; n = 29), treated at a tertiary referral center. MAIN OUTCOME MEASURES: vertigo control, speech perception pre- and postoperatively. RESULTS: Gender, side, and preoperative treatment were similar in all groups. Age was younger in the ESSalone-group with 56.2 ± 13.0 years (CIalone = 64.2 ± 11.4 years; ESS + CI = 63.1 ± 9.7 years). Definitive MD was present in all the CIalone, in 79.3% of the ESS + CI and in 59.6% of the ESSalone-patients. Likewise, vertigo control rate was 100% in the CIalone, 89.7% in the ESS + CI and 66.0% in the ESSalone-group. CONCLUSIONS: Vertigo control was improved in all three groups, however, superior in groups treated with CI, potentially contributed by the manipulation of both the endo- and perilymphatic systems. A more systematic characterization of the patients with larger case numbers and documentation of follow up data would be needed to evaluate a clinical effect more properly.


Assuntos
Implante Coclear , Saco Endolinfático , Doença de Meniere , Percepção da Fala , Humanos , Doença de Meniere/complicações , Doença de Meniere/cirurgia , Doença de Meniere/diagnóstico , Estudos Retrospectivos , Saco Endolinfático/cirurgia , Vertigem/etiologia , Vertigem/cirurgia , Cóclea/cirurgia
5.
HNO ; 71(8): 504-512, 2023 Aug.
Artigo em Alemão | MEDLINE | ID: mdl-37450020

RESUMO

BACKGROUND: Hearing success in bimodally hearing patients with a cochlear implant (CI) and a hearing aid (HA) exhibits different results: while some benefit from bimodal CI and HA, others do not. OBJECTIVE: The aim of this study was to investigate hearing success in terms of speech perception in bimodally fitted patients in relation to the cochlear coverage (CC) of the CI electrodes. MATERIALS AND METHODS: Using the OTOPLAN software (CAScination AG, Bern, Switzerland), CC was retrospectively measured from CT scans of the temporal bone of 39 patients, who were then categorized into two groups: CC ≤ 65% (CC500) and CC > 65% (CC600). Monaural speech intelligibility for monosyllables at a sound pressure level (SPL) of 65 dB in open field was assessed at various timepoints, preoperatively with HA and postoperatively with CI, and compared between the groups. In addition, speech intelligibility was correlated with CC in the entire cohort before surgery and during follow-up (FU). RESULTS: Overall, no significant differences in speech intelligibility were found between CC500 and CC600 patients at any of the FU timepoints. However, both CC500 and CC600 patients showed a steady improvement in speech intelligibility after implantation. While CC600 patients tended to show an earlier improvement in speech intelligibility, CC500 patients tended to show a slower improvement during the first 3 months and a steeper learning curve thereafter. The two patient groups converged during FU, with no significant differences in speech intelligibility. There was no significant relationship between unimodal/unilateral free-field speech intelligibility and CC. However, patients with a CC of 70-75% achieved maximum speech intelligibility. CONCLUSION: Despite a nonsignificant correlation between CC and speech discrimination, patients seem to reach their maximum in unimodal/unilateral speech understanding mainly at 70-75% coverage. However, there is room for further investigation, as CC500 was associated with a shorter cochlear duct length (CDL), and long and very long electrodes were used in both groups.


Assuntos
Implante Coclear , Implantes Cocleares , Percepção da Fala , Humanos , Estudos Retrospectivos , Audição
6.
Eur Arch Otorhinolaryngol ; 280(9): 4009-4018, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36881166

RESUMO

PURPOSE: Disturbance of cochlear microcirculation is discussed as final common pathway of various inner ear diseases. Hyperfibrinogenemia causing increased plasma viscosity is a possible factor for a critical reduction of cochlear blood flow that might lead to sudden sensorineural hearing loss (SSHL). The aim was to determine the efficacy and safety of drug-induced defibrinogenation by ancrod for SSHL. METHODS: Double-blind, randomized, placebo-controlled, multicenter, parallel group, phase II (proof-of-concept) study (planned enrollment: 99 patients). Patients received an infusion of ancrod or placebo (day 1) followed by subcutaneous administrations (day 2, 4, 6). Primary outcome was the change in pure tone audiogram air conduction average until day 8. RESULTS: The study was terminated early due to slow recruiting (31 enrolled patients: 22 ancrod, 9 placebo). A significant improvement of hearing loss was registered in both groups (ancrod: - 14.3 dB ± 20.4 dB, - 39.9% ± 50.4%; placebo: - 22.3 dB ± 13.7 dB, - 59.1% ± 38.0%). A statistically significant group-difference was not detected (p = 0.374). Placebo response of 33.3% complete and 85.7% at least partial recovery was observed. Plasma fibrinogen levels were reduced significantly by ancrod (baseline: 325.2 mg/dL, day 2: 107.2 mg/dL). Ancrod was tolerated well, no adverse drug reaction was of severe intensity, no serious adverse events occurred. CONCLUSION: Ancrod reduced fibrinogen levels that support its mechanism of action. The safety profile can be rated positively. Since the planned number of patients could not be enrolled, no efficacy conclusion can be drawn. The high rate of placebo response challenges clinical trials for SSHL and needs to be considered in future investigations. Trial registrations This study was registered in the EU Clinical Trials Register, EudraCT-No. 2012-000066-37 at 2012-07-02.


Assuntos
Perda Auditiva Neurossensorial , Perda Auditiva Súbita , Humanos , Ancrod/uso terapêutico , Fibrinogênio , Glucocorticoides/uso terapêutico , Perda Auditiva Neurossensorial/tratamento farmacológico , Perda Auditiva Súbita/tratamento farmacológico , Resultado do Tratamento , Estudo de Prova de Conceito
7.
Ann Otol Rhinol Laryngol ; 132(5): 519-526, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-35656811

RESUMO

OBJECTIVE: Betahistine is frequently used in the pharmacotherapy for Menière's Disease (MD). Little is known about its mode of action and prescribed dosages vary. While betahistine had an increasing effect on cochlear microcirculation in earlier studies, low dose betahistine of 0.01 mg/kg bw or less was not able to effect this. Selegiline inhibits monoaminooxidase B and therefore potentially the breakdown of betahistine. The goal of this study was to examine whether the addition of selegiline to low dose betahistine leads to increased cochlear blood flow. METHODS: Twelve Dunkin-Hartley guinea pigs were anesthetized, the cochlea was exposed and a window opened to the stria vascularis. Blood plasma was visualized by injecting fluoresceinisothiocyanate-dextrane and vessel diameter and erythrocyte velocity were evaluated over 20 minutes. One group received low dose betahistine (0.01 mg/kg bw) and selegiline (1 mg/kg bw) i.v. while the other group received only selegiline (1 mg/kg bw) and saline (0.9% NaCl) as placebo i.v. RESULTS: Cochlear microcirculation increased significantly (P < .001) in guinea pigs treated with low dose betahistine combined with selegiline by up to 58.3 ± 38.7% above baseline over a period of up to 11 minutes. In one guinea pig, the increase was 104.6%. Treatment with Selegiline alone did not affect microcirculation significantly. CONCLUSIONS: Low dose betahistine increased cochlear microcirculation significantly when combined with selegiline. This should be investigated in further studies regarding dose-effect relation in comparison to betahistine alone. Side effects, in particular regarding circulation, should be considered carefully in view of the clinical applicability of a combination therapy in patients with MD.


Assuntos
beta-Histina , Doença de Meniere , Animais , Cobaias , beta-Histina/farmacologia , beta-Histina/uso terapêutico , Cóclea , Doença de Meniere/tratamento farmacológico , Selegilina/farmacologia , Selegilina/uso terapêutico
8.
Eur Arch Otorhinolaryngol ; 280(3): 1131-1145, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35965274

RESUMO

PURPOSE: Treatment of Menière's Disease (MD) comprises an array of both non-destructive and destructive treatment options. In patients who are therapy-refractory to non-destructive medical treatment, endolymphatic mastoid shunt surgery (EMSS) is both recommended and debated controversially. The aim of this study was to investigate safety in terms of hearing, vestibular function, complication rate, and efficacy with regards to vertigo control of EMSS in patients with MD according to the current diagnostic criteria of 2015. METHODS: Retrospective analysis of 47 consecutive patients with definite or probable MD with description of demographic parameters, pre- and postoperative MD treatment, pre- and postoperative audiometric (pure tone audiometry) and vestibular (caloric testing) results. The parameters were compared between patients with and without postoperative vertigo control. RESULTS: 31/47 patients (66.0%) had improved vertigo control postoperatively. Postoperative hearing and vestibular preservation were predominantly stable. No significant differences between patients with improved vertigo control and patients with no change or worse vertigo episodes were found. In the treatment refractory group, 4 patients required a revision EMSS and 6 a destructive MD treatment (5 gentamicin intratympanically, 1 labyrinthectomy). No peri- or postsurgical complications were reported. CONCLUSIONS: EMSS was found to be beneficial in two thirds of the patients with definite or probable Morbus Menière and a safe procedure regarding hearing and vestibular preservation with no postoperative complications. Therefore, EMSS should be considered before inducing destructive treatment options, such as intratympanic gentamicin application or labyrinthectomy.


Assuntos
Anastomose Endolinfática , Doença de Meniere , Vestíbulo do Labirinto , Humanos , Doença de Meniere/complicações , Doença de Meniere/cirurgia , Estudos Retrospectivos , Processo Mastoide/cirurgia , Vertigem/etiologia , Anastomose Endolinfática/efeitos adversos , Gentamicinas/uso terapêutico
9.
Eur Arch Otorhinolaryngol ; 280(6): 2695-2705, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36454382

RESUMO

PURPOSE: In children and adolescents, preoperative planning for a semi-implantable bone conduction device (SIBCD) is crucial. The geometric changes of the new version of a common SIBCD should enable a higher rate of successful implantation due to its flatter actuator. Thus, this radioanatomic study compared the rate of successful implantation of both device versions at the traditional mastoidal localization and two alternative sites, retrosigmoidal, and parietal, and investigated parameters helping to estimate the feasibility. METHODS: A retrospective analysis of 136 CT scans of 0 to 20-year-old patients, evaluation of demographic parameters, radioanatomy, and assessment of head diameter was conducted. The feasibility was investigated for certain age groups at three implantation sites. Prediction of feasible implantation by means of different parameters was calculated. RESULTS: A significant higher implantation rate was observed with the new device for all three sites and age groups. The age group of 6-8 years (n = 19) had most striking differences with a 58.1% rate of successful implantation with the new device without spacer (80% with spacer) at the mastoidal localization, whereas none with the old implant. Head diameter was identified as the most predictive parameter regarding all implantation sites (mastoidal: p = 0.030; retrosigmoidal: p = 0.006; parietal: p < 0.0001), age for the mastoidal (p < 0.0001) and retrosigmoidal (p < 0.0001), and gender for the parietal site (p = 0.001). CONCLUSION: The geometric changes of the actuator lead to a higher rate of successful implantation in all age-groups and all three localizations with reducing the requirement for spacers. Parameters age and head diameter might aid in estimating the rate of successful implantation in young patients and may be a novel tool to assist in the decision-making process for a SIBCD.


Assuntos
Condução Óssea , Auxiliares de Audição , Humanos , Criança , Adolescente , Recém-Nascido , Lactente , Pré-Escolar , Adulto Jovem , Adulto , Estudos Retrospectivos , Estudos de Viabilidade , Processo Mastoide/cirurgia , Perda Auditiva Condutiva/cirurgia
10.
BMC Surg ; 22(1): 196, 2022 May 19.
Artigo em Inglês | MEDLINE | ID: mdl-35590282

RESUMO

BACKGROUND: Selective neck dissection (SND) is the surgical treatment of choice in squamous cell carcinoma of the head and neck (HNSCC) with suspected or manifest metastases in the cervical lymph nodes. For SND to be successful, treated lymph node levels should be selected according to anatomic considerations and the extent of the disease. Aim of this study was to identify neck dissection levels that had an impact on individual prognosis. METHODS: We conducted a retrospective review of SND as part of primary treatment of HNSCC. Overall survival (OS) and regional control rates (RCR) were calculated for all patients treated at one academic tertiary referral center. RESULTS: 661 patients with HNSCC were included, 644 underwent ipsilateral and 319 contralateral SND. Average follow-up was 78.9 ± 106.4 months. 67 (10.1%) patients eventually developed nodal recurrence. Tumor sites were oral cavity (135), oropharynx (179), hypopharynx (118) and larynx (229). Tumor categories pT1-pT4a, and all clinical and pathological nodal categories were included. Multivariate analysis indicated improved OS rates for patients undergoing SND in ipsilateral levels I and V as well as level III contralaterally. Analysis for tumor origin showed that SND in ipsilateral level I showed significantly improved OS in HNSCC of the oral cavity. CONCLUSION: The dissection of ipsilateral level I in oral cavity cancer was of particular relevance in our exploratory, retrospective analysis. To clarify the relevance for the determination of the extent of SND, this should be investigated prospectively in a more homogenous patient cohort.


Assuntos
Neoplasias de Cabeça e Pescoço , Esvaziamento Cervical , Neoplasias de Cabeça e Pescoço/cirurgia , Humanos , Recidiva Local de Neoplasia/cirurgia , Estadiamento de Neoplasias , Estudos Retrospectivos , Carcinoma de Células Escamosas de Cabeça e Pescoço/patologia , Carcinoma de Células Escamosas de Cabeça e Pescoço/cirurgia , Resultado do Tratamento
11.
Otol Neurotol ; 43(4): e454-e460, 2022 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-35213480

RESUMO

OBJECTIVE: To evaluate interindividual anatomical variations of the epitympanum and the usable space for implantation of active middle ear implants (AMEI) as well as the usefulness of a tablet-based software to assess individual anatomy on computed tomography (CT) scans. PATIENTS: CT scans of 126 patients, scheduled for cochlea implantation (50.8% men; 0.6-90.0 yr) without middle ear malformations or previous middle ear surgery and with slice thickness ≤0.7 mm were analyzed. MAIN OUTCOME MEASURES: Since no standardized measurements to assess the size of the epitympanum are available, relevant distances were defined according to anatomical landmarks. Three independent raters measured these distances using a tablet-based software. Interrater correlation was computed to evaluate the quality of the measurement process. Descriptive data were analyzed for validation and for evaluation of interindividual anatomical variations. Influence of age and sex on the taken measurements was assessed. RESULTS: No relevant correlation between age or sex and the anatomy of the epitympanum was found. Interrater correlation ranged from Spearman's ρ = 0.3-0.9 and there were significant differences between individual rater results for various combinations. Descriptive data revealed high interindividual anatomical variance of the epitympanum, especially regarding the distance between incus and skull base. CONCLUSION: The reported descriptive data regarding the anatomy of the epitympanum emphasizes the importance of preoperative planning, especially since the height of the epitympanum showed great interindividual variance potentially limiting implantation of AMEIs. The herein used tablet-based software seems to be convenient for preoperative assessment of individual anatomy in the hand of otosurgeons.


Assuntos
Prótese Ossicular , Orelha Média/diagnóstico por imagem , Orelha Média/cirurgia , Feminino , Humanos , Bigorna , Masculino , Software , Tomografia Computadorizada por Raios X
12.
Int J Audiol ; 61(10): 859-867, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34469278

RESUMO

OBJECTIVE: In patients with conductive (CHL) or mixed hearing loss (MHL), hearing rehabilitation with an implantable hearing system, active middle ear implant (AMEI) or a semi-implantable bone-conduction device (SIBCD), is an option when conventional hearing aids are insufficient, or patients are unable to wear them. DESIGN: Retrospective analysis of 20 consecutive patients (24 implants) with a comparison of demographic characteristics and audiometric results (air-bone gap = ABG, effective hearing gain = EHG, functional hearing gain = FHG, Freiburg Monosyllabic Test in quiet, Oldenburg Sentence Test in noise = OLSA). STUDY SAMPLE: Patients, eligible for both devices, who received either AMEI or SIBCD due to CHL or MHL. RESULTS: Analysis showed no significant differences in post-operative functional hearing results between the group of AMEI vs. SIBCD (ABG-reduction: 31.6 ± 12.4 dB HL vs. 28.0 ± 11.8 dB HL; p = 0.702; EHG: -1.6 ± 7.7 dB HL vs. -1.2 ± 4.2 dB HL; p = 0.090; FHG: 33.4 ± 12.6 dB HL vs. 26.1 ± 11.7 dB HL; p = 0.192; Freiburg: 83.0 ± 15.6% vs. 83.6 ± 14.2%; Freiburg-improvement: 57.7 ± 26.8% vs. 68.2 ± 19.7%; p = 0.294; OLSA: -2.7 ± 3.0 SNR vs. -1.4 ± 3.6 SNR; OLSA-improvement: 2.6 ± 2.1 dB vs. 3.7 ± 2.8 dB; p = 0.323). Four patients had the AMEI explanted due to insufficient functioning and later received a SIBCD. CONCLUSIONS: Due to more challenging anatomical conditions, a surgical technique for the AMEI is more complex. However, functional results are comparable to the SIBCD. Therefore, proper patient counselling and cautious choice of the device are mandated before surgery.


Assuntos
Surdez , Auxiliares de Audição , Perda Auditiva , Prótese Ossicular , Percepção da Fala , Condução Óssea , Orelha Média , Perda Auditiva/cirurgia , Humanos , Estudos Retrospectivos , Resultado do Tratamento
13.
J Vestib Res ; 32(3): 271-283, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34151878

RESUMO

BACKGROUND: The diagnosis of Menière's disease (MD) is made according to diagnostic criteria, the last revision of which was in 2015. For diagnosis, symptoms are weighted with audiometric findings and this can be challenging in individual patients. OBJECTIVE: To analyze patient's characteristics and symptoms in a real-life cohort of 96 patients with diagnosed MD regarding sociodemographic parameters, clinical specifics, and audiometry. METHODS: Prospective clinical patient registry containing demographic and socioeconomic parameters, symptoms, as well as pure-tone audiometry data. RESULTS: 31 patients with definite MD, and 36 with probable MD were identified. 29 patients showed typical clinical signs of MD, but did not meet the full diagnostic criteria, and were considered separately. Mean duration of symptoms prior to presentation was 3.9±4.6 years. Significant differences between categories were found regarding aural fullness, tinnitus, and fluctuating hearing. If multiple audiograms were available, 28.6 % (6/21) documented fluctuating hearing. CONCLUSIONS: Current diagnostic criteria probably do not represent patients with monosymptomatic presentation or an early stage very well. Long-term follow-up with repeated audiometry is advisable.


Assuntos
Doença de Meniere , Zumbido , Audiometria de Tons Puros , Humanos , Doença de Meniere/diagnóstico , Estudos Prospectivos , Zumbido/diagnóstico
14.
Eur Arch Otorhinolaryngol ; 279(4): 1851-1861, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34050805

RESUMO

PURPOSE: In cochlear implantation, thorough preoperative planning together with measurement of the cochlear duct length (CDL) assists in choosing the correct electrode length. For measuring the CDL, different techniques have been introduced in the past century along with the then available technology. A tablet-based software offers an easy and intuitive way to visualize and analyze the anatomy of the temporal bone, its proportions and measure the CDL. Therefore, we investigated the calculation technique of the CDL via a tablet-based software on our own cohort retrospectively. METHODS: One hundred and eight preoperative computed tomography scans of the temporal bone (slice thickness < 0.7 mm) of already implanted FLEX28™ and FLEXSOFT™ patients were found eligible for analysis with the OTOPLAN software. Measurements were performed by two trained investigators independently. CDL, angular insertion depth (AID), and cochlear coverage were calculated and compared between groups of electrode types, sex, sides, and age. RESULTS: Mean CDL was 36.2 ± 1.8 mm with significant differences between sex (female: 35.8 ± 0.3 mm; male: 36.5 ± 0.2 mm; p = 0.037), but none concerning side or age. Differences in mean AID (FLEX28: 525.4 ± 46.4°; FLEXSOFT: 615.4 ± 47.6°), and cochlear coverage (FLEX28: 63.9 ± 5.6%; FLEXSOFT: 75.8 ± 4.3%) were significant (p < 0.001). CONCLUSION: A broad range of CDL was observed with significant larger values in male, but no significant differences concerning side or age. Almost every cochlea was measured longer than 31.0 mm. Preoperative assessment aids in prevention of complications (incomplete insertion, kinking, tipfoldover), attempt of atraumatic insertion, and addressing individual necessities (hearing preservation, cochlear malformation). The preferred AID of 720° (two turns of the cochlea) was never reached, opening the discussion for the requirement of longer CI-electrodes versus a debatable audiological benefit for the patient in his/her everyday life.


Assuntos
Implante Coclear , Implantes Cocleares , Cóclea/diagnóstico por imagem , Cóclea/cirurgia , Ducto Coclear , Implante Coclear/métodos , Feminino , Humanos , Masculino , Estudos Retrospectivos , Software , Osso Temporal/diagnóstico por imagem , Osso Temporal/cirurgia
15.
Cancer Biomark ; 33(3): 331-347, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34542062

RESUMO

BACKGROUND: MicroRNAs constitute promising biomarkers. OBJECTIVE: The aim was to investigate diagnostic and prognostic implications of miR-182-5p and miR-205-5p in p16-positive and p16-negative oropharyngeal squamous cell carcinomas (OPSCCs). METHODS: Expression of miR-182-5p, miR-205-5p were determined via quantitative real-time-PCR in fresh frozen tissues of 26 p16-positive, 19 p16-negative OPSCCs and 18 HPV-negative oropharyngeal controls. Associations between miRNA-expression, clinicopathological characteristics and prognosis were analyzed. RESULTS: Higher miR-182-5p expression was associated with significant inferior disease-specific survival for p16-positive OPSCCs (HR = 1.98E+09, 95% CI 0-Inf; P= 0.028) and a similar trend was observed for p16-negative OPSCCs (HR = 1.56E+09, 95% CI 0-Inf; P= 0.051). Higher miR-205-5p expression was associated with an inferior progression-free survival (HR = 4.62, 95% CI 0.98-21.83; P= 0.034) and local control rate (HR = 2.18E+09, 95% CI 0-Inf; P= 0.048) for p16-positive OPSCCs. CONCLUSIONS: Results indicate that miR-182-5p and miR-205-5p can further stratify patients with p16-positive OPSCC into prognostic groups.


Assuntos
Neoplasias de Cabeça e Pescoço , MicroRNAs , Neoplasias Orofaríngeas , Infecções por Papillomavirus , Biomarcadores , Biomarcadores Tumorais/genética , Inibidor p16 de Quinase Dependente de Ciclina/metabolismo , DNA Viral , Humanos , MicroRNAs/genética , Neoplasias Orofaríngeas/genética , Infecções por Papillomavirus/complicações , Infecções por Papillomavirus/diagnóstico , Infecções por Papillomavirus/genética , Prognóstico , Carcinoma de Células Escamosas de Cabeça e Pescoço/genética
16.
Head Neck ; 43(12): 3707-3719, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34591354

RESUMO

BACKGROUND: The prognostic impact of hsa-miRNA-182-5p in oral cancer remains unexplored. Therefore, the aim of this study was to investigate the prognostic value of hsa-miRNA-182-5p and its predicted target kinectin 1 (KTN1) in oral squamous cell carcinoma (OSCC). METHOD: Expression level of hsa-miRNA-182-5p was analyzed in tumor tissue (n = 36) and healthy oral mucosal tissue (n = 17) using quantitative real-time polymerase chain reaction. Protein level of the predicted target KTN1 was detected via immunohistochemistry. Results were validated in a cohort of The Cancer Genome Atlas (TCGA). RESULTS: After dividing the data into a subgroup with high and low hsa-miRNA-182-5p expression level, a significant better overall (p = 0.016), recurrence-free (p = 0.009), and progression-free survival (p = 0.004) was observed in an upregulation of hsa-miRNA-182-5p. Staining intensity of KTN1 showed a reciprocal impact on the prognosis. Validation in a TCGA cohort confirmed these results. CONCLUSION: Our results indicate hsa-miRNA-182-5p and KTN1 as potential biomarkers for OSCC.


Assuntos
Proteínas de Membrana/genética , MicroRNAs , Neoplasias Bucais , Carcinoma de Células Escamosas de Cabeça e Pescoço , Biomarcadores Tumorais/genética , Humanos , MicroRNAs/genética , Neoplasias Bucais/diagnóstico , Neoplasias Bucais/genética , Prognóstico , Carcinoma de Células Escamosas de Cabeça e Pescoço/diagnóstico , Carcinoma de Células Escamosas de Cabeça e Pescoço/genética
17.
Otol Neurotol ; 42(10): 1507-1514, 2021 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-34267101

RESUMO

OBJECTIVE: Hearing rehabilitation with an active middle ear implant (AMEI) in patients with mixed hearing loss (MHL) after multiple ear surgeries is surgically challenging and requires individual solutions in some cases. Our objective was to introduce a feasible novel technique for direct oval window vibroplasty (OW vibroplasty) using a partial ossicular replacement prosthesis (PORP) to ensure stability and enable active and passive sound transmission. DESIGN: Four patients with MHL following multiple middle ear surgeries and indication for an AMEI received direct OW vibroplasty in combination with a customized PORP between the enwrapped actuator and reconstructed tympanic membrane (TM). RESULTS: Postoperative bone conduction was stable in all patients. All patients benefitted from the AMEI in combination with PORP with a mean functional gain of 31.5 ±â€Š17.0 dB. Mean aided postoperative pure tone average was 27.3 ±â€Š2.6 dB. Speech discrimination in quiet at 65 dB with the German Language Freiburg Monosyllabic Test improved for all patients to 68.8 ±â€Š6.3% and in noise with the German Language Oldenburger Sentence Test to -10.4 ±â€Š3.3 dB SNR. No complications were observed. CONCLUSIONS: This novel technique of direct OW vibroplasty extends the portfolio of reconstructive middle ear procedures by combining an intraoperatively customized "off-the-shelf" PORP as a coupler between floating mass transducer (FMT) and a cartilage TM. We found satisfying functional hearing results. Benefits of the reported technique comprise 1) stabilization and optimized coupling of the reconstruction, 2) possibility of passive sound transmission, 3) general feasibility due to great availability of a regular PORP, and 4) flexibility in bridging of large gaps between TM and actuator.


Assuntos
Perda Auditiva Condutiva-Neurossensorial Mista , Perda Auditiva , Prótese Ossicular , Substituição Ossicular , Condução Óssea , Orelha Média/cirurgia , Perda Auditiva/cirurgia , Perda Auditiva Condutiva-Neurossensorial Mista/reabilitação , Perda Auditiva Condutiva-Neurossensorial Mista/cirurgia , Humanos , Substituição Ossicular/métodos , Resultado do Tratamento
18.
Laryngorhinootologie ; 100(8): 618-626, 2021 08.
Artigo em Alemão | MEDLINE | ID: mdl-34077975

RESUMO

OBJECTIVES: As a result of digitalization, the internet embodies the essential information medium. Especially, patients with sudden sensorineural hearing loss (SSNHL) require profound education due to unclear scientific evidence. Thus, our study investigated a German-language internet search about SSNHL. DESIGN: The first 30 Google-search results with the term "Hörsturz" (SSNHL in German) were categorized, readability-statistic with different readability-scores (FRES: 0=complex, 100=easy; FKL; SMOG; GFI) calculated, and misinformation documented. A structured content-analysis was performed with the DISCERN-questionnaire (1=low, 5=high quality). Certification of the Health-On-The-Net-Foundation (HON) assessed the abidance of recommended standards. RESULTS: 18 websites (60.0%) accounted for digital media, 7 (23.3%) manufacturers of medical devices, 2 (6.7%) government institutions, and respectively 1 (3.3%) healthcare provider, support-group, and scientific article. Mean word count was 1307.0±840.2, last update 17.1±32.5 months ago, and FRES 36.1±13.9, with the most difficult text by the scientific article (13.7). Mean of DISCERN was 2.2±0.7 with worst rating of manufacturers of medical devices (1.6±0.5). 2 websites (6.7%) were HON-certified, and 14 (46.7%) contained misinformation. CONCLUSION: Internet-based patient-information should be assessed cautiously due to poor readability, potential conflict of interests, low quality, or wrong information. Hence, healthcare providers and professional associations are urged to provide high-quality patient-information in the internet.


Assuntos
Perda Auditiva Neurossensorial , Idioma , Compreensão , Perda Auditiva Neurossensorial/diagnóstico , Humanos , Internet , Inquéritos e Questionários
19.
Eur Arch Otorhinolaryngol ; 278(6): 1983-2000, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32814982

RESUMO

PURPOSE: p16 overexpression was considered as surrogate marker to identify human papillomavirus (HPV)-associated oropharyngeal squamous cell carcinoma (OPSCCs). METHODS: 102 patients with advanced stage OPSCCs treated primarily by transoral lasermicrosurgery were included. Prognostic associations of p16- and HPV-status were analyzed separately and combined. RESULTS: In contrast to p16, the HPV-status resulted in no significant survival discrepancies (5-year overall survival (OS) HPV-positive 64.9%, HPV-negative 78.7%). Combining both markers, p16-positive (p16-positive/HPV-positive, p16-positive/HPV-negative) and p16-negative/HPV-negative groups demonstrated comparable high survival (OS 78.1% vs. 85.6% vs. 73.6%). Lowest survival was observed for patients with p16-negative/HPV-positive OPSCCs (OS 40.8%). Never smoking patients with p16-positive OPSCCs demonstrated the highest survival, whereas within former/current smokers with p16-positive and p16-negative disease it was comparable low (OS 90.0% vs. 63.0% vs. 57.4%). CONCLUSIONS: p16- and HPV-status should not be considered as equivalent markers for a better prognosis. Furthermore, they should not generally predominate patient associated factors like smoking.


Assuntos
Alphapapillomavirus , Neoplasias de Cabeça e Pescoço , Neoplasias Orofaríngeas , Infecções por Papillomavirus , Inibidor p16 de Quinase Dependente de Ciclina , DNA Viral , Humanos , Neoplasias Orofaríngeas/diagnóstico , Papillomaviridae/genética , Infecções por Papillomavirus/complicações , Infecções por Papillomavirus/diagnóstico , Prognóstico , Carcinoma de Células Escamosas de Cabeça e Pescoço
20.
Eur Arch Otorhinolaryngol ; 278(7): 2517-2528, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33009929

RESUMO

PURPOSE: Adenocarcinoma of the salivary glands is of low incidence and a broad range of histopathological subtypes. Cancer stem cell markers (CSC) might serve as novel prognostic parameters. To date, only a few studies examined the expression of CSC in adenocarcinoma of the salivary glands with diverging results. To further investigate the reliability in terms of prognostic value, a histopathological analysis of CSCs on a cohort of patients with adenocarcinomas of the major salivary glands was performed. METHODS: Tumor samples of 40 consecutive patients with adenocarcinoma of the major salivary gland treated with curative intend at one tertiary center were stained with the CSCs ALDH1, BMI-1, CD44, Nanog, and SOX2. Expression of these markers was correlated with clinicopathological parameters and survival estimates. RESULTS: Correlation of high expression of ALDH1 with higher grading (p < 0.001) and high expression of CD44 with the localization of the neoplasm (p = 0.05), larger tumor size (p = 0.006), positive pN-category (p = 0.023), and advanced UICC stage (p = 0.002) was found. Furthermore, high expression of SOX2 correlated with a negative perineural invasion (p = 0.02). No significant correlation of any investigated marker with survival estimates was observed. CONCLUSION: In conclusion, our study did not find a significant correlation of the investigated CSCs with survival estimates in adenocarcinoma of the major salivary glands. Recapitulating the results of our study in conjunction with data in the literature, the CSCs ALDH1, BMI-1, CD44, Nanog, and SOX2 do not seem to serve as reliable prognostic parameters in the treatment of adenocarcinoma of the salivary glands.


Assuntos
Adenocarcinoma , Isoenzimas , Biomarcadores Tumorais , Humanos , Receptores de Hialuronatos , Células-Tronco Neoplásicas , Prognóstico , Reprodutibilidade dos Testes , Retinal Desidrogenase , Glândulas Salivares
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...